| Meridian Digital Pulse Analyzer (DPA)
|
| Description: |
|
The DPA provides information on arterial wall stiffness and determines the biological age of arteries in less than 3 minutes. This FDA approved, user-friendly, non-invasive device uses a finger probe to observe the changes in pressure, blood flow, velocity and profile throughout the whole pulse wave.
Measurements With The DPA
- Pulse Rate
- Ejection time (Etc)
- Pulse Height (PH) - Pulse amplitude
- Ejection Elastic Index (EEI)-- indicator of Left Ventricle ejection and elasticity of large arteries
- Dicrotic Dilation Index (DDI)- indicator of small artery compliance
- Dicrotic Elastic Index (DEI) - peripheral vessel elasticity (arterioles to veins)
- Software program to measure Heart Rate Variability (HRV)
- Software program will store all patient information
DPA Advantages
- Early detection of arterial wall elasticity and determination of biological arterial age in less than 3 minutes
- Software program tests Heart Rate Variability (HRV) in 5 minutes
- Monitors effectiveness of therapeutic intervention
- Monitors arterial wall response to lifestyles changes / reduction of cardiovascular risk factors
- Non-invasive - uses a LED/Photodiode finger probe sensor.
- Device is FDA approved
- Lightweight and portable (12 lbs)
- User friendly
- Can be used alone (thermal printer) or interfaced with computer for storage of information
- Color printout data sheet when interfaced with user's computer/printer
- Affordable
- Revenue generator
A Powerful New Tool for Health Care Professionals
As a health care professional using the DPA®, you have a powerful new tool and advanced technology providing you with cardiovascular parameters specific to the health of arteries. In minutes, an easy-to-understand report and the precise data you require is available for identifying cardiovascular disease risk in your patients.
This non-invasive system is capable of measuring arterial compliance. The DPA® sensitivity to early arterial changes builds highly detailed data for assessment in determining whether patients have potential underlying vascular disease, as well as developing an outline for the physician of the potential effects of patient-specific risk factors.
Advanced Technology Arrives In Your Practice
The DPA® device measures a pulse waveform produced by the beating heart. Data captured by the DPA® during a patient test is analyzed and reported in just minutes to provide a clear, concise evaluation tool for health care professionals.
Arterial stiffness indices are particularly important in identifying individuals who exhibit the development of vascular disease, and enables the healthcare professional to begin appropriate treatment long before the symptoms or clinical signs appear. The DPA has many applications including:
- Hypertension
- Borderline Hypertension
- Hyperlipidemial
- Endothelial Function
Getting started: Simple, quick and painless for physician and patient
Your practice already has everything you need to begin using the DPA® today, and your patients' comfort and ease during the test is assured.
To begin the test, the appropriate patient-specific data is collected through a series of questions. As your patient rests comfortably, an arterial finger pulse sensor is placed on the left finger. The instrument's monitor displays the waveform as it is sensed. Once data is collected and analyzed, you simply print the DPA Report.
The DPA® is a portable and easy-to-use "plug and play" system that requires no additional accessories or disposable components. Enjoy the following benefits:
- Minimal capital outlay
- Low monthly payments financing available
- Per-patient-test revenue
- CPT codes available for Screenings
Reference Ranges
The reference ranges are based on a comparable set of values obtained from similar healthy subjects. It is possible that an abnormal value may be normal for you but they should be discussed with your physician as only they are qualified to make a determination as to the significance and/or make a diagnosis.
Prevention
One purpose of this screening is to prevent disease before symptoms occur. In those instances where symptoms have developed, laboratory tests results help confirm that a problem does exist. But a normal test result is just as significant as an abnormal result. A normal result does not mean that a test was unnecessary. When a result is normal, it not only helps rule out disease, but is also establishes a baseline "normal". A person's own result is the best baseline for monitoring any change that takes place in the future.
Almost everyone in this country knows about heart disease. They know the importance of prevention, detection, and treatment and the huge impact it has on people's health. But they know very little about vascular disease outside the heart.
Early Detection is Vital
In most cases, with early detection, vascular disease can be treated effectively. The DPA test is a simple screening test that may detect these potential problems, all of which are non-invasive and painless. The beauty of the screening is that it is very simple. The tests do not produce any risk or discomfort for patients, and can be done in a matter of minutes.
|
|
ATTENTION HEALTHCARE PROFESSIONALS: EQUIPMENT PURCHASE NOW INCLUDES YOUR TRAINING .... CALL 1-800-768-9182 FOR MORE DETAILS
| |